| Upgrade NMEA 0183 equipment to NMEA 2000! |
| Upgrade NMEA 0183 equipment to NMEA 2000! |
|
| |
|
The NMEA 2000 transmits data through Controller Area Network (CAN bus). It simplifies the connection and shares information among different devices by using a single trunk cable. Compared with NMEA 0183 in “RS422” interface, NMEA 2000 has better transmission reliability and shares data easily in a network.
NK-80 is a gateway between NMEA 0183 electronics devices and NMEA 2000 device/network. NK-80 allows users to connect NMEA 2000 network with their existing NMEA 0183 devices.
Key Feature of NK-80:
‧Upgrade NMEA 0183 equipment to NMEA 2000 ‧Conversion between NMEA 2000 and NMEA 0183 ‧Full NMEA 2000 compliance ‧Full NMEA 0183 compliance ‧Compact size, easy for installation ‧Isolation between NMEA 0183 and NMEA 2000 ‧Fully galvanically isolated for electrical spike protection |
|
 |
|
APPLICABLE STANDARDS |
|
NMEA 2000 standard version1.2 (2004) |
|
NMEA 2000 CAN BUS LINE TRANSMITTER |
|
Parameter |
Conditions |
Min. |
Max. |
|
Recessive bus voltage |
VTXD = VDD; no load. |
2.0V. |
3.0V. |
|
Dominant bus voltage NET-H |
VTXD = 0.8V |
2.75V |
4.5V |
|
Dominant bus voltage NET-L |
VTXD = 0.8V |
0.5V |
2.25V |
|
Recessive differential output voltage |
VTXD = 2V; no load |
-500mV |
50mV |
|
Dominant differential output voltage |
40Ω < RL < 60Ω |
1.5V |
3.0V |
|
NMEA 2000 CAN BUS LINE RECEIVER |
|
NET-H, NET-L common-mode input resistance |
typical 100 KΩ |
|
Differential input resistance |
typical 100 KΩ |
|
INPUT/OUTPUT |
|
Configurable |
4,800, 9,600, 38,400 (default), |
|
Baud rate |
57,600, 115,200 bps |
|
ENVIRONMENTAL |
|
Operation Temperature |
-20°C~+55°C |
|
Storage Temperature |
-25°C~+70°C |
|
Water Proofing |
IP54 |
|
Humidity |
0~80%RH |
|
PHYSICAL |
|
Length |
132 mm |
|
Width |
30 mm |
|
Height |
22.8 mm |
|
Cable Lengths |
NMEA 2000 cable: 0.1m NMEA 0183 cable: 1 m |
|
Weight |
< 150 g |
|
ELECTRICAL |
|
NMEA 2000 Load Equivalency Number (LEN) |
1 (under 50 mA) |
|
POWER SUPPLY |
|
Supply Voltage from CAN Bus |
12VDC / 24VDC (Typical) | |
|
|
 |
|